← All sites
Diligence underway

Cicero Industrial Building Opportunity

Cicero Avenue corridor, south suburban Cook County, IL

Land and building20.7 acresAbout 95,000 SF target areaREPORTED
Potential total powerNot yet setTotal power not establishedUNKNOWN
Time to first powerNot yet setStarts at the existing serviceUNKNOWN
First powerAbout 3 MWReported; sources differCONFLICT
The opportunity

Overview

About 95,000 SF of a 390,000 SF industrial building on a 20.7-acre lot in the south suburbs, with about 3 MW of existing service reported and a carrier's fiber equipment on site.

Key facts

Land and building
20.7-acre lot · about 95,000 SF target area in a 390,000 SF buildingREPORTED
Potential total power
Not establishedUNKNOWN
Time to first power
Not established yet; the plan is to start from the existing serviceUNKNOWN
First power
Existing power on site: about 3 MW reported (3,600 A at 480 V per the brochure; an older drawing shows 1,600 A)CONFLICT

LandUp's view

Our view

A small-scale project built around an existing service. A written utility allocation for the target area is the next document we need. ESTIMATE

Power

Existing service
Owner brochure: 3,600 A at 480 V (about 3 MVA). Older floor plan: 1,600 A plus backup. No utility letterCONFLICT
Allocation
Capacity assignable to the target area is not documentedUNKNOWN

Grid

Nearest substation
138 kV substation about 1.2 mi; several 138 kV lines within 0.5 miESTIMATE

Gas

Gas
Not studiedUNKNOWN

Fiber

Fiber
A carrier's fiber equipment is on site; a second carrier is unconfirmedVERIFIEDSite photos, Oct 10 2026

Building and land

Clear height
24 ft 4 in to beam undersideREPORTED
Structure
Metal deck on joists; slab thickness unknownUNKNOWN
Space
The target area is the interior, its roof and one parking fieldREPORTED

Location

Location
Cicero Avenue corridor, south suburban Cook County, ILREPORTED
Flood
Address is in the minimal-hazard zone; flood zone within about 0.25 miVERIFIEDFEMA flood map, Oct 15 2026

What is and is not established

Electrical service
About 3 MW reported; figures differ between sources; no utility letterCONFLICT
Utility capacity
Allocation to the target area not documentedUNKNOWN
Zoning
Not yet confirmed in writingUNKNOWN
Environmental
Phase I not yet seenUNKNOWN
Structural
Slab and roof data not yet obtainedUNKNOWN

VERIFIED: seen in a document or on site by LandUp. REPORTED: told to us by the utility, an owner or a broker; not yet seen in a document. ESTIMATE: our estimate. CONFLICT: sources disagree. UNKNOWN: not yet established. Nothing on this page is a utility commitment or a development approval.